Adjusting the rising hinge mechanism

keywords

Separation does not close

Applicable to the following series/designs

IBIZA2000 and NOVA2000 designs with swing or two part hinged doors and rising hinge mechanism

In our care instructions, we state that the lifting/lowering screw must be retightened once a year for maintenance reasons.

If this is not done, the bearing plate may twist internally, thereby changing the position of the door panel.

In this case, you must:

  • loosen the hexagon socket screw when the door is closed and lowered
  • open the door panel 90° and close it again
  • retighten the Allen screw in the position in which you want the door panel to remain

Please note that the door panel must be completely lowered when closed.

Kermi Duschdesign Service Hebe-Senk-Mechanismus einstellen